金相試樣切割機(jī)的設(shè)計(jì)
金相試樣切割機(jī)的設(shè)計(jì),金相,試樣,切割機(jī),設(shè)計(jì)
河南科技學(xué)院 2009屆本科畢業(yè)設(shè)計(jì)(論文),設(shè)計(jì)題目:金相試樣切割機(jī)的設(shè)計(jì) 學(xué)生姓名: 張靜 所在院系: 機(jī)電學(xué)院 所學(xué)專(zhuān)業(yè): 機(jī)電技術(shù)教育 導(dǎo)師姓名: 劉貫軍,【摘 要】: 金相試樣切割機(jī)主要用于金相試樣的截取和各種材料的下料、切口等,在冶金、汽車(chē)、航空航天等制造業(yè)中應(yīng)用極為廣泛。20世紀(jì)90年代后,金相制樣技術(shù)發(fā)展極為迅速,金相試樣切割機(jī)作為金相取樣設(shè)備也取得了很大的進(jìn)步。 本設(shè)計(jì)通過(guò)對(duì)金相試樣切割機(jī)的整體造型、機(jī)械結(jié)構(gòu)和控制系統(tǒng)進(jìn)行了分析,完成了切割機(jī)主體結(jié)構(gòu)的設(shè)計(jì),控制系統(tǒng)采用了銑床導(dǎo)軌原理,實(shí)現(xiàn)了低成本和手動(dòng)化。 最后確定切割機(jī)的裝配總圖。通過(guò)此次設(shè)計(jì),掌握了相關(guān)設(shè)計(jì)的主要步驟,并對(duì)于Pro—E軟件應(yīng)用方面有了進(jìn)一步的提高。,1 引言 金屬零件的力學(xué)性能不僅與它的化學(xué)成分有關(guān),也與它的金相組織密切有關(guān)。金相檢驗(yàn)是控制和評(píng)定產(chǎn)品質(zhì)量不可缺少的重要手段,是科學(xué)研究中研究新材料、新工藝和提高金屬制品內(nèi)在質(zhì)量的重要方法。 要進(jìn)行金相分析,就必須制備能用于微觀檢驗(yàn)的樣品— 金相試樣。通常,金相試樣的制備要經(jīng)過(guò)取樣、鑲嵌、磨光和拋光幾個(gè)步驟。每個(gè)步驟都應(yīng)該細(xì)心操作,因?yàn)槿魏坞A段上的失誤都可能影響最后的結(jié)果,因?yàn)檫@可能會(huì)造成組織假象,從而得出錯(cuò)誤的結(jié)論。金相試樣的制備是通過(guò)切割機(jī)、鑲嵌機(jī)、磨/拋光機(jī)來(lái)完成。金相試樣的截取是金相試樣制備過(guò)程中一個(gè)重要環(huán)節(jié)。截取試樣的方法有手鋸、鋸床、砂輪切割機(jī)和線切割機(jī)等等。根據(jù)零件的形狀和材料,選擇適當(dāng)?shù)姆椒▉?lái)切割。,目前砂輪切割機(jī)廣泛應(yīng)用于金相試樣的截取上,主要原因是其適應(yīng)性強(qiáng),樹(shù)脂砂輪片可切割軟的金屬零件如銅、鋁及合金和硬的金屬零件如淬火后的碳鋼、高速鋼;金剛石切割機(jī)可切割超硬材料如硬質(zhì)合金、陶瓷等。另外其切割速度快、勞動(dòng)強(qiáng)度低、操作簡(jiǎn)便和切割成本低。選擇可靠性高的金相試樣切割機(jī),可以提高制樣效率和質(zhì)量,降低成本,提高經(jīng)濟(jì)效益。,金相試樣切割機(jī)主要特點(diǎn):本切割機(jī)的切割砂輪直接固定在與電動(dòng)機(jī)的軸同軸線相連接的軸上,利用滑板箱的橫向和縱向的移動(dòng)來(lái)切割固定在鉗口中的試樣 電動(dòng)機(jī)固定在底座上,軸套套在電動(dòng)機(jī)的軸上,砂輪片由螺母和夾片加以固定。固定在電動(dòng)機(jī)的前面的滑板箱上裝有可沿縱向移動(dòng)的加緊裝置,由手柄的轉(zhuǎn)動(dòng)來(lái)移動(dòng)鉗口把試樣夾緊在鉗座中,當(dāng)轉(zhuǎn)動(dòng)手柄時(shí),就可以進(jìn)行試樣切割了。機(jī)器工作時(shí),由罩殼將砂輪片等檔住,以防冷卻液飛濺和砂輪片碎裂時(shí)飛出傷人,2 設(shè)計(jì)要求 金相試樣切割機(jī)的具體設(shè)計(jì)要求為: (1)利用Pro--E軟件設(shè)計(jì) (2)確定結(jié)構(gòu)的尺寸 (3)繪制相應(yīng)的零件圖、實(shí)體圖及總裝配圖,3 切割機(jī)的總體設(shè)計(jì)過(guò)程 3.1 電動(dòng)機(jī)的選擇,,3.2 傳動(dòng)機(jī)構(gòu)的設(shè)計(jì) 3.2.1 軸的計(jì)算 3.2.2 軸的結(jié)構(gòu)設(shè)計(jì),,3.3 控制系統(tǒng)的設(shè)計(jì) 3.3.1夾具的主要結(jié)構(gòu)與使用,,3.3.2 進(jìn)給機(jī)構(gòu)的設(shè)計(jì),,,,上 滑 板,,,中 滑 板,,,下 滑 板,,,進(jìn) 給 裝 置,4 用Pro—E軟件對(duì)切割機(jī)進(jìn)行實(shí) 體造型和裝配 4.1 切割機(jī)各主要零件的實(shí)體造型,,軸 的 實(shí) 體 圖,,上 滑 板 的 實(shí) 體 圖,,中 滑 板 的 實(shí) 體 圖,,下 滑 板 的 實(shí)體 圖,,進(jìn) 給 系 統(tǒng) 的 實(shí)體 圖,4. 2 切割機(jī)的裝配,,切 割 機(jī) 的 內(nèi) 部 實(shí) 體 圖,5 結(jié)束語(yǔ) 在此次設(shè)計(jì)的過(guò)程中,培養(yǎng)了我的綜合運(yùn)用所學(xué)知識(shí)的能力,分析和解決實(shí)際中所遇到問(wèn)題的能力,并且能鞏固和深化我所學(xué)的專(zhuān)業(yè)知識(shí),使我在調(diào)查研究和收集資料等方面有了顯著的提高,同時(shí)在理解分析能力、制定設(shè)計(jì)計(jì)算和繪圖能力方面有較大的進(jìn)步;另外我的技術(shù)分析和組織工作的能力也有一定程度的提高。,致謝 非常感謝學(xué)院領(lǐng)導(dǎo)和老師給我提供了這次良好的深入學(xué)習(xí)的機(jī)會(huì)和寬松的學(xué)習(xí)環(huán)境。通過(guò)這次畢業(yè)設(shè)計(jì),不但使我將大學(xué)期間所學(xué)的專(zhuān)業(yè)知識(shí)再次回顧學(xué)習(xí),而且也使我學(xué)到了專(zhuān)業(yè)領(lǐng)域中一些前沿的知識(shí)。非常感謝在本次設(shè)計(jì)中曾給予我耐心指導(dǎo)和親切關(guān)懷的老師及幫助過(guò)我的同學(xué),正是由于他們的幫助和鼓勵(lì)才使我能夠在畢業(yè)設(shè)計(jì)過(guò)程中克服種種困難,最終順利完成論文,他們的學(xué)識(shí)和為人也深深地影響著我。在此,請(qǐng)?jiān)试S我再次向曾直接給予我多次指導(dǎo)的導(dǎo)師表示最忠誠(chéng)的敬意!同時(shí)也感謝百忙之中前來(lái)參加答辯的各位老師、專(zhuān)家和教授!,敬請(qǐng)指導(dǎo)批正!!!,謝謝!!! 答辯人:張靜,河南科技學(xué)院本科生畢業(yè)論文(設(shè)計(jì))課題審核表
院(系)名稱(chēng)
機(jī)電學(xué)院
專(zhuān)業(yè)名稱(chēng)
機(jī)電技術(shù)教育042
指導(dǎo)教師姓名
劉貫軍
課題名稱(chēng)
金相試樣切割機(jī)設(shè)計(jì)
課題來(lái)源
自擬課題
立題理由
和所具備
的條件
金相試樣切割機(jī)種類(lèi)很多,但適合本院專(zhuān)業(yè)實(shí)驗(yàn)室條件的用于制做透射電鏡樣品精密切割的切割機(jī)卻很少見(jiàn),國(guó)外有符合要求的此類(lèi)產(chǎn)品,但價(jià)格昂貴。隨著科研工作的深入,設(shè)計(jì)制做一種高精度低成本的金相試樣切割機(jī)很有必要,而且設(shè)計(jì)條件已經(jīng)具備。
教研室
審批意見(jiàn)
教研室主任簽字: 年 月 日
畢業(yè)論文(設(shè)
計(jì))工作領(lǐng)導(dǎo)
小組審批意見(jiàn)
組長(zhǎng)簽字:: 年 月 日
注:本表存院(系)備查。
學(xué)生姓名
張靜
班級(jí)
機(jī)教042
指導(dǎo)教師
劉貫軍
論文(設(shè)計(jì))題目
金相試樣切割機(jī)的設(shè)計(jì)
目前已完成任務(wù)
1.制定畢業(yè)設(shè)計(jì)計(jì)劃
2.查找相關(guān)文獻(xiàn)
3.完成畢業(yè)論文開(kāi)題報(bào)告
是否符合任務(wù)書(shū)要求進(jìn)度:符合
尚需完成的任務(wù)
1.繼續(xù)對(duì)論文材料進(jìn)行組織和整理;
2.按照論文提綱,有步驟有計(jì)劃的開(kāi)展論文工作,存在問(wèn)題要及時(shí)與老師溝通;
3.對(duì)已完成的論文內(nèi)容進(jìn)行檢查審核,力求把問(wèn)題降到最少;
4.到規(guī)定的時(shí)間完成論文初稿;
5.根據(jù)指導(dǎo)老師的指導(dǎo)意見(jiàn)和全部材料完成論文;
能否按期完成論文(設(shè)計(jì)):能
存在問(wèn)題和解決辦法
存
在
問(wèn)
題
閱讀資料不足,對(duì)論文主題的研究不夠透徹,且相關(guān)的理論知識(shí)還不夠全面;
與指導(dǎo)老師的交流不夠充分。
擬
采
取
的
辦
法
繼續(xù)查找資料,加強(qiáng)對(duì)相關(guān)理論知識(shí)的理解和掌握,應(yīng)多和老師交流,在老師的指導(dǎo)下更好完成設(shè)計(jì)。
指導(dǎo)教師簽 字
日期
年 月 日
教學(xué)院長(zhǎng)(系主任)
意 見(jiàn)
簽字: 年 月 日
河南科技學(xué)院本科畢業(yè)論文(設(shè)計(jì))中期進(jìn)展情況檢查表
河南科技學(xué)院本科生畢業(yè)論文(設(shè)計(jì))任務(wù)書(shū)
題目名稱(chēng) 金相試樣切割機(jī)的設(shè)計(jì)
學(xué)生姓名
張靜
所學(xué)專(zhuān)業(yè)
機(jī)教
學(xué)號(hào)
20040315049
指導(dǎo)教師姓名
劉貫軍
所學(xué)專(zhuān)業(yè)
機(jī)械設(shè)計(jì)
職稱(chēng)
教授
完成期限
2008 年 11 月 01 日 至 2009 年 05 月 24 日
一、論文(設(shè)計(jì))主要內(nèi)容及主要技術(shù)指標(biāo)
1、連接金相試樣切割機(jī)的主要用途,國(guó)內(nèi)外研究及使用狀況(包括選擇國(guó)內(nèi)市場(chǎng)上此類(lèi)產(chǎn)品的性能及不足);
2、研究制定設(shè)計(jì)方案;
3、對(duì)受力構(gòu)件進(jìn)行受力分析并有必要計(jì)算后方可進(jìn)行設(shè)計(jì)制圖;
二、 畢業(yè)論文(設(shè)計(jì))的基本要求
1、 通過(guò)互聯(lián)網(wǎng)、校內(nèi)期刊數(shù)據(jù)庫(kù)等途徑了解切割機(jī)的工作原理、分析存在問(wèn)題,提出改進(jìn)方案;
2、 學(xué)習(xí)并熟練使用Pro—E繪圖軟件,并用其進(jìn)行零件和產(chǎn)品設(shè)計(jì)(重要部件應(yīng)有受力分析),提交任務(wù)內(nèi)的全部零件圖及部件總成圖。
3、 完成不少于2000字(單詞)的專(zhuān)業(yè)英文資料翻譯。
三、畢業(yè)論文(設(shè)計(jì))進(jìn)度安排
2008年11月1日—12月30日 查找相關(guān)專(zhuān)業(yè)資料,熟悉Pro—E繪圖軟件的使用,提交開(kāi)題報(bào)告,論證設(shè)計(jì)方案、完成不少于2000單詞英文資料翻譯稿。
2009年2月16日—5月16日 基本完成畢業(yè)設(shè)計(jì)規(guī)定的繪圖任務(wù)。
2009年5月17日—5月24日 撰寫(xiě)畢業(yè)論文(設(shè)計(jì)說(shuō)明書(shū))。
2009年5月24日交齊全部畢業(yè)設(shè)計(jì)資料。
畢業(yè)設(shè)計(jì)(論文)開(kāi)題報(bào)告
題目名稱(chēng): 金相試樣切割機(jī)
學(xué)生姓名
張靜
專(zhuān)業(yè)
機(jī)電技術(shù)教育
班級(jí)
042
一、選題的目的意義
目前,正處在科學(xué)技術(shù)飛速發(fā)展的信息時(shí)代,自動(dòng)化、最優(yōu)化、集成化、智能化和精密化等使現(xiàn)代機(jī)械制造行業(yè)正經(jīng)歷著巨大的變化,也是其今后發(fā)展的必然趨勢(shì).金相取樣設(shè)備作為其中一個(gè)重要分支,正在由原來(lái)的手工操作逐漸走向半自動(dòng)化和自動(dòng)化.為此,我設(shè)計(jì)了對(duì)金相切割的半自動(dòng)化控制系統(tǒng).
與此同時(shí)在設(shè)計(jì)的過(guò)程中,能培養(yǎng)我綜合運(yùn)用所學(xué)知識(shí),分析和解決實(shí)際中所遇到的問(wèn)題,并且能鞏固和深化我所學(xué)的專(zhuān)業(yè)知識(shí),使我在調(diào)查研究和收集資料等方面有了顯著的提高,同時(shí)在理解分析能力、制定設(shè)計(jì)或試驗(yàn)方案能力、設(shè)計(jì)計(jì)算和繪圖能力方面有較大的進(jìn)步;另外我的技術(shù)分析和組織工作的能力也有一定程度的提高。
希望在此次畢業(yè)設(shè)計(jì)中,充分發(fā)揮出我們的創(chuàng)新能力,樹(shù)立良好的學(xué)術(shù)思想和工作作風(fēng),牢牢把握住這次走上崗位之前的實(shí)踐機(jī)會(huì),充分鍛煉出自己的工作能力。
二、國(guó)內(nèi)外研究綜述
金屬零件的力學(xué)性能不僅與它的化學(xué)成分有關(guān),也與它的金相組織密切有關(guān)。金相檢驗(yàn)是控制和評(píng)定產(chǎn)品質(zhì)量不可缺少的重要手段,是科學(xué)研究中研究新材料、新工藝和提高金屬制品內(nèi)在質(zhì)量的重要方法。
要進(jìn)行金相分析,就必須制備能用于微觀檢驗(yàn)的樣品— — 金相試樣。通常,金相試樣的制備要經(jīng)過(guò)取樣、鑲嵌、磨光和拋光幾個(gè)步驟。每個(gè)步驟都應(yīng)該細(xì)心操作,因?yàn)槿魏坞A段上的失誤都可能影響最后的結(jié)果,因?yàn)檫@可能會(huì)造成組織假象,從而得出錯(cuò)誤的結(jié)論。金相試樣的制備是通過(guò)切割機(jī)、鑲嵌機(jī)、磨/拋光機(jī)來(lái)完成。金相試樣的截取是金相試樣制備過(guò)程中一個(gè)重要環(huán)節(jié)。截取試樣的方法有手鋸、鋸床、砂輪切割機(jī)和線切割機(jī)等等。根據(jù)零件的形狀和材料,選擇適當(dāng)?shù)姆椒▉?lái)切割。目前砂輪切割機(jī)廣泛應(yīng)用于金相試樣的截取上,主要原因是其適應(yīng)性強(qiáng),樹(shù)脂砂輪片可切割軟的金屬零件如銅、鋁及合金和硬的金屬零件如淬火后的碳鋼、高速鋼;金剛石切割機(jī)可切割超硬材料如硬質(zhì)合金、陶瓷等。另外其切割速度快、勞動(dòng)強(qiáng)度低、操作簡(jiǎn)便和切割成本低。選擇可靠性高的金相試樣切割機(jī),可以提高制樣效率和質(zhì)量,降低成本,提高經(jīng)濟(jì)效益。
金相試樣切割機(jī)主要特點(diǎn):本切割機(jī)的切割砂輪直接固定在與電動(dòng)機(jī)的軸同軸線相連接的軸上,利用滑板箱的橫向和縱向的移動(dòng)來(lái)切割固定在鉗口中的試樣 電動(dòng)機(jī)固定在底座上,軸套套在電動(dòng)機(jī)的軸上,砂輪片由螺母和夾片加以固定。固定在電動(dòng)機(jī)的前面的滑板箱上裝有可沿縱向移動(dòng)的加緊裝置,由手柄的轉(zhuǎn)動(dòng)來(lái)移動(dòng)鉗口把試樣夾緊在鉗座中,當(dāng)轉(zhuǎn)動(dòng)手柄時(shí),就可以進(jìn)行試樣切割了。機(jī)器工作時(shí),由罩殼將砂輪片等檔住,以防冷卻液飛濺和砂輪片碎裂時(shí)飛出傷人。
三、畢業(yè)設(shè)計(jì)主要研究?jī)?nèi)容
1、研究切割機(jī)的切割原理;
2、利用Pre-E軟件繪制切割機(jī)模型;
3、繪制相應(yīng)的零件圖及總裝配圖
四、畢業(yè)設(shè)計(jì)(論文)的研究方法和技術(shù)路線
1.采用理論和實(shí)際操作相結(jié)合的方式再結(jié)合現(xiàn)代設(shè)計(jì)理念的基礎(chǔ)上,利用現(xiàn)有的條件來(lái)進(jìn)研究。
2.結(jié)合指導(dǎo)教師的教學(xué)經(jīng)驗(yàn)來(lái)重新完善和提高自己新的認(rèn)識(shí)和研究。
3.大量查閱有關(guān)書(shū)籍和資料來(lái)擴(kuò)充自己視野與認(rèn)識(shí),提高理論成果的技術(shù)含量。
4.充分利用互連網(wǎng)來(lái)查找最新技術(shù)成果,提高自身的創(chuàng)新意識(shí)。
五、主要參考文獻(xiàn)與資料獲得情況
[1]成大先。機(jī)械設(shè)計(jì)手冊(cè)[M]。北京:化學(xué)工業(yè)出版社,2004
[2]成大先。機(jī)械設(shè)計(jì)手冊(cè) 第四版[M]。北京:化學(xué)工業(yè)出版社,2002
[3]毛謙德,李振清。袖珍機(jī)械設(shè)計(jì)手冊(cè) 第三版[M]。北京:機(jī)械工業(yè)出版社,2007
[4]機(jī)械設(shè)計(jì)實(shí)用手冊(cè)編委會(huì)。 機(jī)械設(shè)計(jì)實(shí)用手冊(cè)[M] 。北京:機(jī)械工業(yè)出版社,2008
[5]陳立德。 機(jī)械設(shè)計(jì)基礎(chǔ)課程設(shè)計(jì)[M]。北京:高等教育出版社,2006
[6]濮良貴,紀(jì)名剛。機(jī)械設(shè)計(jì) 第八版[M]。北京:高等教育出版社,2007
[7]朱金波。Pro—E 3.0 工業(yè)產(chǎn)品設(shè)計(jì)完全掌握[M]。北京:兵器工業(yè)出版社,2007
[8]金鑫,陳雪梅,賈長(zhǎng)治。Pro—E 3.0中文版機(jī)械設(shè)計(jì)專(zhuān)家指導(dǎo)教程[M]。 北京:機(jī)械工業(yè)出版社,2007
[9] 曹巖。Pro—E 3.0 機(jī)械設(shè)計(jì)實(shí)例精解[M]。北京:機(jī)械工業(yè)出版社,2007
[10]朱文堅(jiān),黃平,吳昌林。機(jī)械設(shè)計(jì)[M]。北京:機(jī)械工業(yè)出版社,2005
[11]朱龍根。機(jī)械設(shè)計(jì)[M]。北京:機(jī)械工業(yè)出版社,2006
[12]吳克堅(jiān),于曉紅,錢(qián)瑞明。機(jī)械設(shè)計(jì)[M]。北京:高等教育出版社,2003
六、指導(dǎo)教師審批意見(jiàn)
年 月 日
The electroless nickel-plating on magnesium alloy using NiSO4d6H2O
as the main salt
Jianzhong Lia,*, Zhongcai Shaob, Xin Zhanga, Yanwen Tiana
aSchool of materials and metallurgy, Northeastern University, Shenyang 110004, China
bFaculty of Environment and Chemical Engineering, Shenyang Institute of Technology, Shenyang 110168, China
Received 23 July 2004; accepted in revised form 19 December 2004
Available online 26 January 2005
Abstract
In this paper, the electroless nickel-plating on magnesium alloy was studied, using NiSO4d 6H2O as the main salt in the electroless plating
alkaline solutions. The effects of the buffer agent and plating parameters on the properties and structures of the plating coatings on
magnesium alloy were investigated by means of scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDS) and Xray
diffraction (XRD). In addition, the weight loss/gain of the specimens immersed in the test solution and plating bath was measured by
using the electro-balance, to evaluate the erosion of the alloy in the plating solutions. The adhesion between the electroless plating coatings
and the substrates was also evaluated. The compositions of the non-fluoride and environmentally friendly plating bath were optimized
through Latin orthogonal experiment. The buffer agent (Na2CO3) added to the plating bath was found to be useful in increasing the growth
rate of the plating coating, adjusting the adhesion between the electroless plating coatings and the substrates, and maintaining the pH value
within the range of 8.5–11.5, which is required for the successful electroless nickel-plating on magnesium alloy with NiSO4d 6H2O as the
main salt. Trisodium citrate dihydrate was found to be an essential component of the plating bath to plate magnesium alloy, with an optimum
concentration of 30 g L_1. The obtained plating coatings are crystalline with preferential orientation of (111), having advantages such as lowphosphorus
content, high density, low-porosity, good corrosion resistance and strengthened adhesion.
D 2004 Elsevier B.V. All rights reserved.
Keywords: Magnesium alloy; Electroless plating; Buffer; Corrosion resistance; Adhesion
1. Introduction
The use of magnesium alloys in a variety of applications,
particularly in aerospace, automobiles, and mechanical and
electronic components, has increased steadily in recent years
as magnesium alloys exhibit an attractive combination of
low density, high strength-to-weight ratio, excellent castability,
and good mechanical and damping characteristics.
However, magnesium is intrinsically highly reactive and its
alloys usually have relatively poor corrosion resistance,
which is actually one of the main obstacles to the
application of magnesium alloys in practical environments
[1–3].
Hence, the application of a surface engineering technique
is the most appropriate method to further enhance the
corrosion resistance. Among the various surface engineering
techniques that are available for this purpose, coating by
electroless nickel is of special interest especially in the
electronic industry, due to the possession of a combination
of properties, such as good corrosion and wear resistance,
deposit uniformity, electrical and thermal conductivity, and
solderability etc. As far as magnesium alloys are concerned,
the main salts of electroless plating solutions mostly focus
attentions on basic nickel carbonate or nickel acetate [4–9],
which result in high-cost, low-efficiency, instability of
electroless plating solutions and little applications. In
addition, the basic nickel carbonate or nickel acetate of
plating solutions yet including fluoride, are harmful to the
environment, therefore, it is urgently needed to develop new
environmentally friendly plating bath. It is difficult to carry
0257-8972/$ - see front matter D 2004 Elsevier B.V. All rights reserved.
doi:10.1016/j.surfcoat.2004.12.009
* Corresponding author. Tel.: +86 24 8368 7731; fax: +86 24 2398 1731.
E-mail address: mengsuo66@163.com (J. Li).
Surface & Coatings Technology 200 (2006) 3010– 3015
www.elsevier.com/locate/surfcoat
out electroless plating on magnesium alloys due to the highcorrosion
rate of magnesium alloys in the plating bath with
NiSO4d 6H2O or NiCl2d 6H2O as the main salt. It is reported
[10] that the corrosion rate of magnesium and its alloys in
NaCl solutions solely depends on the pH of the buffered
chloride solutions. The objective of this study was to find a
buffer agent and determine how the buffer agent affects the
dissolution of magnesium alloy in NiSO4d 6H2O alkaline
solutions, and the non-fluoride plating solutions for magnesium
alloy with NiSO4d 6H2O as the main salt. The
microstructure, compositions and corrosion behavior of
the coatings were investigated in detail.
2. Experimental
The substrate material used in the research was AZ91D
ingot-cast alloy. The chemical composition of the alloy is
given in Table 1.
Substrates with a size of 50 mm_40 mm_20 mm were
used in the research. The substrates were mechanically
polished with emery papers up to 1000 grit to ensure similar
surface roughness. The polished substrates were thoroughly
washed with distilled water before passing through the precleaning
procedure as shown in Table 2.
The substrates were air-dried after the fluoride activation
(the last step in the pre-cleaning procedure). In a typical
experiment, the initial weight of a air-dried substrate was
measured and then quickly transferred to the plating bath
(1000 mL) in a glass container placed in a water bath with a
constant temperature of 80 8C. A fresh bath was used for each
experiment to avoid any change in concentration of bath
species. The bath compositions and other parameters used in
these experiments are given through Latin orthogonal
experiment in Table 3.
Final weights of the specimens were determined and the
coating rates in micrometer per hour were calculated from
the weight gain. At the same time, in order to study the each
buffer’s influence on the substrates and find a buffer
appropriate for the electroless plating on magnesium alloy,
test solutions with compositions similar to those of the
plating bath except that sodium hypophosphite was not
added, were prepared to simulate the corrosion rates of
magnesium alloy in plating bath and the behaviors of the
buffers. Duplicate experiments were conducted in each case,
and the coating rate reported is the average of two
experiments. The growth rates of the plating coating were
measured using the electro-balance made in America, which
is the 0.1 mg precision. In the research, the pH value of
plating bath was monitored by a pHS-25C model of
precision pH/mV meter. Morphology of the coatings was
analyzed using a scanning electron microscope. The energy
dispersive X-ray spectroscopy analysis was used for
determining the content of phosphorus in the coatings.
Crystallinity of the coatings was investigated by Rigaku D/
max-rA X-ray diffractometer with Cu K-alpha radiation.
The adhesion strength of the electrolessly deposited nickel
coatings to the magnesium alloy substrates was determined
by scratch test. During the scratch test, the specimen was
moved at a constant speed of approximately 11.4 mm/min.
Scratches were generated on the specimen using a diamond
indenter with a spherical tip of 300 Am in diameter.
Corrosion potential measurement in 3.5 wt.% NaCl solution
was carried out to comparatively investigate the corrosion
behaviors of the bare substrate and the nickel-plated
substrates. The electrochemical cell used for corrosion
potential measurement consisted of a bare substrate or a
nickel-plated substrate as the working electrode (exposed
area: 1 cm2), a saturated calomel electrode (SCE), and a
platinum-foil counter electrode.
Table 1
Chemical composition of the AZ91D alloy (in wt.%)
Al Mn Ni Cu Zn Ca Si K Fe Mg
9.1 0.17 0.001 0.001 0.64 b0.01 b0.01 b0.01 b0.001 Bal
Table 2
Optimized pre-cleaning procedure
Table 3
Optimized bath composition and parameters
Bath species and parameters Quantity
NiSO4d 6H2O 25 g/L
NaH2PO2d H2O 30 g/L
C6H5Na3O7d 2H2O 30 g/L
Na2CO3 30 g/L
NH3d H2O Adjusting pH
pH value 11
Temperature 80F2 8C
J. Li et al. / Surface & Coatings Technology 200 (2006) 3010–3015 3011
3. Results and discussion
3.1. The buffers’ behaviors in the test NiSO4 solutions and
the choice of an appropriate buffer
Fig. 1 shows the variation of weight loss of magnesium
alloy as a function of the immersion time with different
buffers in the test solutions. The compositions and the
controlled temperature of the test solutions were similar to
those of the plating bath except that sodium hypophosphite
was not included. The pH values of the test solutions were
adjusted by NH3d H2O to fix at 11. The weight loss increases
linearly with the immersion time increasing of magnesium
alloys in the Na2CO3, Na2
B4O7, and CH3COONa test
solutions. It is revealed in Fig. 1 that the corrosion rates
were constant throughout the examined immersion time.
As recognized from the slope of each solid line in Fig. 1,
corrosion rate in the test solution containing Na2CO3
buffer is the lowest among the three tested buffers. The
obtained slopes are 0.015, 0.022 and 0.056 mg cm_2
min_1 for Na2CO3, Na2
B4O7 and CH3COONa buffers,
respectively. These results can be explained in terms of
dissociation constants of the corresponding acids, which
are k 2=4.7_10_11 ( k 1=4.4_10_7 ) , k 2=1_10_9
(k1=1_10_4), and k=1.75_10_5 for H2CO3, H2B4O7 and
CH3COOH, respectively. The second dissociation constant
of a binary acid decides the buffer capability of the buffer.
Obviously, the Na2CO3 buffer has the lowest cost and best
buffer capability among the tested buffers.
Fig. 2 shows the weight loss of the substrates versus
immersion time in the test solutions with pH values at 9, 10
and 11, using Na2CO3 as the buffer. Corrosion of the
specimens in non-buffered test solutions with pH values at
9, 10 and 11 was also investigated. The corresponding
weight loss curves are shown in Fig. 2. All test solutions
used for these experiments had compositions similar to
those in the plating bath except that sodium hypophosphite
was not included. The weight loss linearly changes with the
increase of the immersion time in all cases shown in Fig. 2.
Under the same pH value, the corrosion rate of the
substrates in the buffer solution is obviously lower than
that of the substrates in the non-buffered solution, as shown
by the slopes of the curves in Fig. 2. This suggests that the
buffer solution has a considerable effect on the corrosion
rate of magnesium alloy. In both the Na2CO3 buffered and
non-buffered test solutions, the corrosion rates of magnesium
alloy decrease with the increase of the pH value. This
indicates the weight-loss of the substrates is related to the
reaction between the substrate metal and the hydrogen ions.
But the corrosion reaction between the substrate metal and
the hydrogen ions goes gradually on, because the low
concentration of hydrogen ions is presented in the plating
alkaline solutions. And then, the concentration of hydrogen
ions is weakly decreased during the test progress. This leads
to the constant corrosion rates in the short test time, which is
shown in Figs. 1 and 2. At the same time, knowing that for
Mg(OH)2 Ksp at 25 8C=8.9_10_12 at pH 9, [OH_]=10_5 M,
most Mg2+ diffused into plating solution to form up to 10_2
M. At pH 11, [OH_]=10_3 M, the [Mg2+] couldn’t exceed
10_6 M, thus most Mg2+ formed Mg(OH)2 and stayed near
the substrate. Mg(OH)2 could increase the adsorption
energy barrier and reduce the corrosion rate. Therefore,
higher pH resulted in lower corrosion rate. As to the
Na2CO3 buffered solutions, for MgCO3 Ksp at 25 8C=10_15,
in test solutions, [Na2CO3]N0.1 M, thus the possible
[Mg2+]b10_14 M. This means that the driving force for
Mg to form Mg2+ was very low. Instead of dissolving Mg,
the CO3
2_ ion would bond or be adsorbed to the substrate
surface to form local Mg—CO3
2_. In this case, the substrate
surface area exposed to H2O or H+ was reduced a lot,
0 5 10 15 20 25 30 35
-0.2
0.0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
Na(CH3COO)
Na2B4O7
Na2CO3
Weight loss/mg.cm-2
Time/min
Fig. 1. The variation of weight loss of magnesium alloy in test solutions
with different buffers.
0 5 10 15 20 25 30 35
0
1
2
3
4
5
solution
pH=9
pH=10
pH=11
pH=9
pH=10
pH=11
Weight loss/mg.cm-2
Time/min
in non-buffered solution
in Na2CO3 buffered
Fig. 2. The variation of weight loss of magnesium alloy in test solutions
with different pH values.
3012 J. Li et al. / Surface & Coatings Technology 200 (2006) 3010–3015
leading to lower corrosion rates. The pKa2 for Na2CO3 is
10.33, at pH lower than 10.33 some CO3
2_ ions formed
HCO3
_. Reaction Mg+2HCO3
_=MgCO3+H2 potentially
existed. At pH higher than 10.33, [HCO3
_] is negligible.
Therefore in Fig. 2, we can see that the corrosion rate at pH
11 was not reduced as much, compared the rate at 10.
H2B4O7 and CH3COOH don’t have such advantages.
3.2. The effects of plating parameters on coatings
The coating rate, surface appearance, and adhesion of the
coatings at different concentrations of Na2CO3 buffer are
listed in Table 4. The critical load (LC) was measured under
progressive loading conditions, which can be used to
accurately characterize the adhesion strength of the deposit/
substrate system [13]. The adhesion between the coatings and
substrates decreases obviously with the increase of the
concentration of Na2CO3. Surface appearance of the plating
coatings becomes gradually shining with the increase of the
Na2CO3 concentration. Grave corrosion of the substrates was
found in the non-buffered plating bath. The growth rate of the
coatings noticeably increases with the increase of the Na2CO3
concentration. Considering the combination of growth rate,
surface appearance, and adhesion of the coatings, the
optimum concentration of the Na2CO3 buffer was determined
to be 30 g L_1.With this concentration, the purpose of adding
Na2CO3 in plating bath is commendably achieved.
In the research, it was found that the pH value of plating
bath had a considerable effect on the growth rate and the
surface appearance of the coatings. The hydrogen ions in
plating bath were not only astricted by the CO3
2_ ions
dissociated from the buffer Na2CO3, but linked with the OH_
ions. When the pH value of the plating bath was below 8.5,
point corrosion or dark gray coatings were obtained and the
coating growth rate was low. When the pH value of the
plating bath was above 11.5, the adhesion between coatings
and substrates were deteriorated, although the growth rate
and the surface appearance of the coatings were satisfying.
During the electroless plating, the pH value of the plating bath
was monitored with a pHS-25C model of precision pH/mV
meter. In this research, the preferred pH range of the plating
bath for electroless plating on magnesium alloy is 8.5–11.5.
Table 4
Coating rate, surface appearance and adhesion of the coatings obtained
from the plating bath with different amounts of Na2CO3
Concentration of
Na2CO3 (g L_1)
Coating rate
(Am/h)
Surface appearance LC (N)
0 – Grave corrosion –
10 12.32 Point corrosion 81
20 16.41 Dark gray 76
30 18.32 Shining 73
40 18.91 Shining 61
50 19.26 Shining 51
20 30 40 50 60 70
13
14
15
16
17
18
19
20
The coating thickness/ìm
The trisodium citrate dihydrate content/g.L-1
Fig. 3. Relationship between the coating thickness and the trisodium citrate
dihydrate concentration.
30 40 50 60
1000
2000
3000
4000
5000
6000
7000
8000
Intensity
2è /( o )
Fig. 4. XRD patterns of the electroless plating coating.
Fig. 5. Surface morphology of a plating coating.
J. Li et al. / Surface & Coatings Technology 200 (2006) 3010–3015 3013
Fig. 3 shows the variation of coating thickness on
magnesium alloy at same plating time as a function of the
trisodium citrate dihydrate concentration at constant temperature
and pH. The coating thickness decreases with the
increase of the trisodium citrate dihydrate concentration.
According to De Minjer and Brenner’s explanation [11], at
low concentrations the low adsorption of ligand on the
catalytic surface of the substrate accelerates the plating
reaction. At higher concentration, there is a high adsorption
of ligand on the surface, which slows down the plating
reaction. But when the concentration was below 20 g L_1,
the plating bath became destabilized and nickel precipitate
was observed.
3.3. Properties of the plating coatings from nickel sulfate
The coating obtained under optimized bath composition
was probably preferentially crystallized (see Fig. 4). The only
and strong diffraction observed in the XRD spectrum
corresponds to the (111) peak of nickel. Fig. 5 shows the
surface morphology of the plating coating. The surface is
optically smooth and of low porosity. No obvious surface
damage was observed. The compositions of the plating
coating were determined to be 5.39 wt.% P and 94.61 wt.%
Ni by energy dispersive X-ray spectroscopy. Fig. 6 shows the
cross section of an electroless plating coating. The coating
has a good adhesion to the substrate and no cracks or holes
were observed.
Fig. 7 shows the curve of the Ni–P coating free corrosion
potential with time. After the sample was immersed in 3.5
wt.% NaCl solution at room temperature for 2 h, the free
corrosion potential of the coated magnesium alloy
approached to about _0.4 V. The steady-state working
potential of magnesium electrode is generally about _1.50
V, although its standard potential is _2.43 V [14]. This
indicates the improved corrosion resistance of the plating
coatings prepared in this research, compared with the bare
alloy.
The adhesion between the coatings and the substrates
was evaluated by means of quenching and the scratch test.
The plated specimens were heated at a temperature of 250
8CF10 8C for 1 h, and then quenched in the cold water. This
process was repeated for 20 times on each specimen. No
discoloration, cracks, blisters, or peeling was observed [12].
For the scratch test, the critical load (LC) of 73 N was found
for the coatings obtained in the optimized bath composition
and parameters. These results suggest the excellent adhesion
of the plating coating to the substrate.
3.4. Proposed mechanism of the electroless plating nickel
Even under the same pH value, the magnesium alloy
exhibits better corrosion resistance in the Na2CO3 buffered
plating solution than in the non-buffered plating solution.
Fig. 6. Cross section view of an electroless plating coating.
0 1 2 3 4 5 6 7 8
-0.46
-0.44
-0.42
-0.40
-0.38
-0.36
-0.34
-0.32
-0.30
ESCE/V
× 103, time/s
Fig. 7. Curve of the Ni–P coating free corrosion potential with time.
3014 J. Li et al. / Surface & Coatings Technology 200 (2006) 3010–3015
Fig. 8 gives a simple model to explain this phenomenon.
Large amount of H2 gas is produced in the electroless
plating process. Most of the H+ ions are taken out by the H2
gas bubbles and combine with the CO3
2_, to form HCO3
_.
Therefore, a very thin layer of dilute H+ solution is formed
near the surface of substrate. The Ni2+ ions react with the
magnesium atoms to form the autocatalysis nickel, which
leads to the deposition of the Ni–P coating. If the
concentration of the CO3
2_ ions is low, more H+ ions will
be free and erode the thin Ni–P coating and the substrate. If
the concentration of the CO3
2_ ions is much higher, the H+
ions concentration in the thin dilute H+ solution layer near
the substrate surface will be much lower. Therefore almost
no corrosion process will exist in the interface between the
Ni–P coating and the su
收藏